Available with us is a wide array of Gas Leak Detectors for LPG and CNG. These systems works as the complete gas-leaking alarming products that are ideal for detecting the leakage of particular gas and alarms. It gives out both audio as well as video alarming facility. Known for their efficient working and longer service life, all the systems offered by us are described below:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Mounting Type | Wall Mount |
| Sensor Type | SEMICONDUCTOR |
| Display Type | SEVEN SEGMENT DISPLAY |
| Power Source | AC/DC VOLTAGE |
| Measuring Range | 0-999 ppm |
| Alarm Type | VISUAL AND AUDIBLE |
| Brand | TINSELPRO |
| Measurement Range | 0-1000 ppm |
| Resolution (PPM) | 0.1 PPM |
| Response Time (s) | 15 SEC |
| Sensor Life | 5 YEARS |
| Voltage | 220 V |
| Sensitivity | 1 ppm |
| Color | WHITE |
| Accuracy | 95 % |
| Distance To The Panel | AS ACTUAL |
| Has Vibrating Alarm | No |
| Voltage (V) | 12 V |
| Material | ABS PVC |
| Warranty | 1 YEARS |
| Operating Time | 1.5 MINUTES APPROX. |
| Detecting Principle | SEMICONDUCTOR |
| Weight (g) | 375 G |
| Operating Temp. (deg. Celsius) | 0 to 55 |
| Temperature Range (deg. Celsius) | 0 TO 55 |
| Installation Type | FIXED TYPE |
| Sound Level (dB) | 80 db |
| Model | TPGS0501AF1P PGS0501BF1P |
| Detection Range (%) | UPTO 1000 PPM |
| Alarming Method | PIEZOELECTRIC BUZZER |
| Alarm Current (mA) | 150 MA |
| Gases Measured | NH3 |
| Optional Function | RELAY OUTPUT |
| Alarm Frequency (Hz) | 50 HZ |
| Power Consumption (W) | 2 WATT |
| Output Current | 150 mA |
| Sensitivity (PPM) | 10 TO 999 PPM |
| Output Signal (mA) | 150MA |
| Working Humidity (%) | 95% |
| Reponse Time (s) | 15 SECONDS |
| Warm Up Time | 1.5 MINUTES APPROX. |
| Sound Level | 80db |
| Humidity | 95 |
| Current Consumption | 100mA |
| Frequency Hertz | 50 Hz |
| Indication | VISUAL AND AUDIBLE |
| Product Weight | 375 g |
| Features | 7 SEGMENT DISPLAY WITH RELAY OUTPUT |
| Outputs | 2.5 TO 5 V |
| Gas Type | Ammonia Gas |
| Condition | New |
AmmoniaLeak Detector is a colorless gas with a characteristic pungent smell. It is lighter than air, its density being 0.589 times that of air.The sensing element of Ammonia Gas Detector is a metal oxide semiconductor which has low conductivity in clean air. In the presence of a detectable gas, the sensor''s conductivity increases depending on the gas concentration in the air. A simple electrical circuit can convert the change in conductivity to an output signal which corresponds to the gas concentration. The Ammonia Gas Detector has high sensitivity to ammonia gas. The sensor can detect concentrations as low as 1 ppm in the air and is ideally suited to critical safety-related applications such as the detection of ammonia leaks in refrigeration systems and ammonia detection in the agricultural field has been fabricated with high-tech methodologies using well tested material at our manufacturing unit.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Gas Type | LPG |
| Detection Method | Semiconductor |
| Detector Type | Fixed Single Gas |
| Sampling Method | Diffusion |
| Output Signal | Relay |
| Name of Gases Detected | LPG |
| Power Source | Plug-In |
| Pump | No |
| Humidity | <95% |
| Resolution | Led Indicators |
| Color | White |
| Voltage | Avilable In : 230V AC/ 24V DC/ 12V DC |
| Warranty | 1 Year |
| Display Type | Analog |
| Operating Temperature | 0 To 55 |
| Weight | 600 Grams |
| Alarm Type | Automatic Alarming |
| Model | New Domestic Type 4 |
| Brand | Tinselpro |
| Sensor Type | Semiconductor |
| Usage/Application | Commercial |
| Measuring Range | 0 To 999 PPM |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Gas Type | CFC |
| Detection Method | Semiconductor |
| Sampling Method | Diffusion |
| Output Signal | Relay |
| Power Source | 220V SC/24V DC / 12V DC |
| Brand | TINSELPRO |
| Display Type | LCD |
| Alarm Indication | Audible, Visual |
| Measurement Range | 0 to 999 PPM |
| Resolution | 0.1% |
| Detecting Principle | Semiconductor |
| Weight | 350 gms |
| Current | Less Than150 mA (In measuring condition) Less Than75 mA (In non measuring condition) |
| Optional Function | Gas shut off valve, Relay output for exhaust fan, Input to Central Security System |
| Detected Gas | R-134A/R-12/R-22 |
| Operating Temperature | 0 to 55 Degree C |
| Operating Humidity | Less Than 95% |
| Display Mode | Digital display with seven segment screen |
| Alarming Method | Automatic Alarming |
| Sound Level | Grater Than 80 Decible |
| Power Supply | 230 Volts AC/ 12 Volts DC/ 24 Volts DC |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Piece |
| Output signal | Relay |
| Model | TP0051 |
| Warranty | 1 Year |
| Pump | No |
| Alarm Type | Automatic |
| Sensor type | Semiconductor |
| Ingress rating | IP20 |
| Name of Gases Detected | Co |
| Response time | T90 <30 s |
| Weight | 600 Grams |
| Humidity | <95% |
| Measuring Range | 0 To 999 PPM |
| Display Type | Analog |
| Power Source | Plug-In |
| Brand | TINSELPRO |
| Detector Type | Fixed Single Gas |
| Country of Origin | Made in India |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Unit |
| Name of Gases Detected | CNG |
| Sensor Type | Semiconductor |
| Alarm Type | Audio Visual |
| Measuring Range | 0-999 ppm |
| Accuracy | 95% |
| Brand | TINSELPRO |
| Measurement Range | 0 to 999 PPM |
| Response Time | 2 sec |
| Certification | CE |
| Detecting Principle | Semiconductor |
| Alarming Method | Automatic Alarming |
| Optional Function | Gas shut off valve,Relay output for exhaust fan,Input to Central Security System |
| Resolution | 0.1% |
| Sound Level | Grater Than 80 Db |
| Power Supply | 230 Volts AC/ 12 Volts DC/ 24 Volts DC |
| Weight | 350 gms |
| Current | Less Than 150 mA (In measuring condition) Less Than75 mA (In non measuring condition) |
| Detected Gas | CNG |
| Operating Temperature | 0 to 55 Degree C |
| Operating Humidity | Less Than 95% |
| Display Mode | Digital display with seven segment screen |
We are offering Tinsel Pro CNG Gas Leak Detector to our clients.
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Unit |
| Name Of Gases Detected | Methane |
| Type of Sensor | Semi Conductor |
| Sensor Type | Semiconductor |
| Mounting Type | Fixed/Wall Mounted |
| Brand | TINSELPRO |
| Measuring Range | 0 TO 1000 |
| Response Time | 3-5 SEC |
| Measurement Range | 0 to 999 PPM |
| Voltage | 24 v |
| Power Source | DC |
| Weight | 350 gms |
| Detecting Principle | Semiconductor |
| Current | Less Than 150 mA (In measuring condition) Less Than75 mA (In non measuring condition) |
| Optional Function | Gas shut off valve, Relay output for exhaust fan, Input to Central Security System |
| Detected Gas | CH4 |
| Resolution | 0.1% |
| Operating Temperature | 0 to 55 Degree C |
| Operating Humidity | Less Than 95% |
| Display Mode | Digital display with seven segment screen |
| Alarming Method | Automatic Alarming |
| Sound Level | Grater Than 80 Decible |
| Power Supply | 230 Volts AC/ 12 Volts DC/ 24 Volts DC |
Additional Information: